Dimensions on the profile sketch in millimetres
PRODUCT PROPERTIES – FOR AN AESTHETICALLY SOPHISTICATED FACADE CLADDING
PROPERTIES | UNIT | WP60 VB | WP80 VB | WP100 VB | WP120 VB | WP140 VB | WP150 VB | WP160 VB | WP170 VB | WP200 VB |
---|---|---|---|---|---|---|---|---|---|---|
CORE THICKNESS (h) | mm | 60 | 80 | 100 | 120 | 140 | 150 | 160 | 170 | 200 |
U-VALUE | W/m².K | 0.39 | 0.28 | 0.22 | 0.19 | 0.16 | 0.15 | 0.14 | 0.13 | 0.11 |
TECHNICAL PROPERTIES
OUTER SHELL | Optical profile slightly lined (LL), optionally micro lined (ML) or flat (GL) Heat-treated fully galvanised steel Steel thicknesses 0.50mm – 0.63mm – on request 0.75mm Polyester colour coating (POL) 25µm standard, other coating systems up to 200μm available |
INSULATION CORE | CFC- and HCFC-free, approx. 96% closed-cell, density approx. 40kg/m³ Polyurethan hard foam (PUR) or polyisocyanurat hard foam (PIR) WLS 023 FRC B-s2,d0 / B-s1,d0, flame retardant according to EN 13501.1 |
INNER SHELL | Optical profile slightly lined (LL), optionally micro lined (ML) or flat (GL) Heat-treated fully galvanised steel Steel thicknesses 0.40mm – 0.45mm – 0.50mm – 0.63mm – on request 0.75mm DU-coating similar to white standard, other colours and coating systems up to 200μm available |
OTHER | Large range of standard colours – Special colours on request. Installation with load distribution plate (LVP)* recommended CE-marking according to EN 14509 |
EXTRAS (on request) | Load distribution plates – must be ordered separately Production and transport of excess lengths |
PRODUCT CHARACTERISTICS
A large number of panel types can be realised thanks to the different surface shapes of the covering shells, the choice in colours and the visible and concealed fixing. In terms of its geometry and joint design the sandwich panel wall is optimally adapted to the intended use. This ensures best airtightness values and the highest thermal insulation requirements are met. For technical reasons, it is possible that the panel joint may vary depending on the production plant and core thickness. We recommend the use of load distribution plates (LVP)* for the installation of O-METALL® wall panels with concealed fixing. |
SUITABLE ACCESSORIES