Dimensions Profile sketch in millimetres
PRODUCT PROPERTIES – THE WALL DESIGNPANEL WITH EXCELLENT ACOUSTIC PROPERTIES (VB)
PROPERTIES | UNIT | BSW50 AK-VB | BSW60 AK-VB | BSW80 AK-VB | BSW100 AK-VB | BSW120 AK-VB | BSW150 AK-VB | BSW170 AK-VB | BSW200 AK-VB | BSW220 AK-VB | BSW240 AK-VB |
---|---|---|---|---|---|---|---|---|---|---|---|
CORE THICKNESS (h) | mm | 50 | 60 | 80 | 100 | 120 | 150 | 170 | 200 | 220 | 240 |
U-VALUE | W/m².K | 0.76 | 0.64 | 0.49 | 0.39 | 0.33 | 0.27 | 0.23 | 0.20 | 0.18 | 0.17 |
RW-VALUE | dB | 31 | 31 | 34 | 35 | 35 | 35 | 35 | 35 | 35 | 35 |
SOUND ABSORPTION | aw | 0.90 | 0.90 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 |
SOUND ABS.-CLASS | A-E | – | – | – | A | A | A | A | A | A | A |
TECHNICAL PROPERTIES
OUTER SHELL | Optical profile slightly lined (LL), optionally micro lined (ML) or flat (GL) Heat-treated fully galvanised steel, steel thicknesses 0.50mm – 0.63mm – on request 0.75mm Polyester colour coating (POL) 25µm standard, other coating systems available up to 200μm |
INSULATION CORE | Mineral wool insulation core, shear-resistantly connected with outer and inner shell Density approx. 100kg/m³ Euroclass A2-s1,d0, non-combustible |
INNER SHELL | Optical profile flat (GL) with acoustic perforation Heat-treated fully galvanised steel, steel thicknesses 0.50 to 0.63mm DU-coating similar to white standard |
OTHER | Plug-in system for hidden fixing – installation with load distribution plates (LVP)* recommended CE-marking according to EN 14509 |
EXTRAS (on request) | Load distribution plates (LVP)* – must be ordered separately Outer and inner shell available in aluminium – colours on request |
PRODUCT CHARACTERISTICS
O-METALL® fire protection panels for wall acoustics with „hidden fixing“ (VB) are particularly suitable when high demands are made in regards to aesthetics, sound insulation and evtl. to fire protection. The hidden fixing but also the possibilities in terms of designing the outer shell will help you responding to the aesthetic requirements for your external façade. For technical reasons, the panel joint may vary depending on the production line and core thickness in question. We strongly recommend the use of *load distribution plates (LVP) for the installation of O-METALL® wall panels with concealed fixing (VB). |
SUITABLE ACCESSORIES