*Standard width, other wall widths on request / Dimensions Profile sketch in millimetres
PRODUCT PROPERTIES – THE ACOUSTIC WALL PANEL WITH VISIBLE FIXING (SB)
PROPERTIES | UNIT | BSW50 AK-SB | BSW60 AK-SB | BSW80 AK-SB | BSW100 AK-SB | BSW120 AK-SB | BSW150 AK-SB | BSW170 AK-SB | BSW200 AK-SB | BSW220 AK-SB | BSW240 AK-SB |
---|---|---|---|---|---|---|---|---|---|---|---|
CORE THICKNESS (h) | mm | 50 | 60 | 80 | 100 | 120 | 150 | 170 | 200 | 220 | 240 |
U-VALUE | W/m².K | 0.76 | 0.64 | 0.49 | 0.39 | 0.33 | 0.27 | 0.23 | 0.20 | 0.18 | 0.17 |
RW-VALUE | dB | 31 | 31 | 34 | 35 | 35 | 35 | 35 | 35 | 35 | 35 |
SOUND ABSORPTION | aw | 0.90 | 0.90 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 | 0.95 |
SOUND ABS.-CLASS | A-E | – | – | – | A | A | A | A | A | A | A |
TECHNICAL PROPERTIES
OUTER SHELL | Optical profile slightly lined (LL), micro lined (ML), ridged (GS) or flat (GL) Heat-treated fully galvanised steel, steel thicknesses 0.50mm – 0.63mm – on request 0.75mm Polyester colour coating (POL) 25µm standard, other coating systems available up to 200μm |
INSULATION CORE | Mineral wool insulation core, shear-resistantly connected with outer and inner shell Density approx. 100kg/m³ Euroclass A2-s1,d0, non-combustible |
INNER SHELL | Optical profile flat (GL) with acoustic perforation Heat-treated fully galvanised steel, steel thicknesses 0.50 to 0.63mm DU-coating similar to white standard |
OTHER | Plug-in system for visible fixing CE-marking according to EN 14509 |
EXTRAS (on request) | Other effective widths (up to max. 1200mm) are possible Outer and inner shell available in aluminium – colours on request |
PRODUCT CHARACTERISTICS
O-METALL® fire protection panels for wall acoustics with „visible fixing“ (SB) are particularly suitable when high demands are made in regards to the sound insulation and evtl. to fire protection. Depending on the use, the size or the location of the building specific sound insulation requirements will maybe have to be observed and this will make it necessary to go for O-METALL® acoustic wall panels. For technical reasons, the panel joint and the effective width may vary depending on the production line and core thickness in question. |
SUITABLE ACCESSORIES